CLKSRC=0, INITAK=0, LOOPB=0, LISTEN=0, BORM=0, WUPM=0, CANE=0, SLPAK=0
MSCAN Control Register 1
INITAK | Initialization Mode Acknowledge 0 (0): Running - The MSCAN operates normally. 1 (1): Initialization mode active - The MSCAN has entered initialization mode. |
SLPAK | Sleep Mode Acknowledge 0 (0): Running - The MSCAN operates normally. 1 (1): Sleep mode active - The MSCAN has entered sleep mode. |
WUPM | WakeUp Mode 0 (0): MSCAN wakes on any dominant level on the CAN bus. 1 (1): MSCAN wakes only in case of a dominant pulse on the CAN bus that has a length of Twup. |
BORM | Bus-Off Recovery Mode 0 (0): Automatic bus-off recovery (see Bosch CAN 2.0A/B protocol specification). 1 (1): Bus-off recovery upon user request. |
LISTEN | Listen Only Mode 0 (0): Normal operation. 1 (1): Listen only mode activated. |
LOOPB | Loopback Self Test Mode 0 (0): Loopback self test disabled. 1 (1): Loopback self test enabled. |
CLKSRC | MSCAN Clock Source 0 (0): MSCAN clock source is the oscillator clock. 1 (1): MSCAN clock source is the bus clock. |